1 – CLI Overview
Page 10 Airborne™ Product Family CLI Reference Guide 100-8005-101G
Quatech, Inc. Confidential
1.4.3 Bridging from a TCP connection on the wl-tunnel-port
The Module supports a tunneling feature that allows bridging between a specific TCP
address/port and the Module’s serial port. TCP port tunneling is supported by the wl-tunnel,
wl-tcp-mode, and wl-tunnel-port commands. The rules for TCP connections to the wl-
tunnel-port are as follows:
wl-tunnel must be enabled (set to 1).
wl-tunnel-mode must be set to tcp or udp.
wl-tunnel-port must be set to a non-zero value which is not the same as the
Web Server port or the telnet port.
The CLI Session on the serial interface must be in LISTEN Mode.
There are no other CLI Sessions currently bridged.
If all of the previous conditions are met, this TCP connection will become the active bridge. All
data payload will be bridged between the CLI Session on the serial interface and the CLI
Session on this TCP port.
Note:
The data bridge may terminate for any of the following reasons:
The close CLI command is issued from a secondary TCP CLI
Session.
The other host terminates the TCP connection.
The connection inactivity timer (specified by wl-tcp-timeout)
expires.
Escape sequence detection.
After the data bridge is terminated, the CLI Session on the serial interface remains in LISTEN
Mode and escape detection is enabled if configured.