DS-100
Two Channel RS-232 Asynchronous
Serial Adapter
for ISA compatible machines
User's Manual
QUATECH, INC. TEL: (330) 655-9000
5675 Hudson Industrial Parkway FAX: (330) 655-9010
Hudson, Ohio 44236 http://www.quatech.com
INTERFACE CARDS FOR IBM PC/AT AND PS/2
Vista de página 0
1 2 3 4 5 6 ... 41 42

Resumo do Conteúdo

Página 1 - User's Manual

DS-100Two Channel RS-232 AsynchronousSerial Adapterfor ISA compatible machinesUser's ManualQUATECH, INC. TEL: (330) 655-90005675 Hudson Industria

Página 2 - Warranty Information

3. Windows 2000 ConfigurationWindows 2000 maintains a registry of all known hardware installed in the computer. Inside thehardware registry Windows 2

Página 3 - Corporation

2. Double click on the “Add New Hardware” icon.3-2 Quatech Inc.

Página 4 - Declaration of Conformity

3. The next window will be the “Welcome to the Hardware Wizard”, click “Next”.4. Next choose the “Add/Troublshoot a device” radio button, click “Next”

Página 8 - 2. Installation

7. Next select “Ports (COM & LPT)”, click “Next”.3-7 Quatech Inc.

Página 9 - 2-2 Quatech Inc

8. In the next window under manufacture select “(Standard port types), and under Models select“Communications Port.Because Windows will not detect plu

Página 10 - 3. Windows 2000 Configuration

9. Next you will have to change the “Input/Output Range” to a setting that is not in use “Noconflicts” by choosing a different “Basic Configuration”..

Página 11 - 3-2 Quatech Inc

10. The “Input Request” (IRQ) must be set to corresponds with the jumpers setting on theDS-100 board.3-10 Quatech Inc.

Página 12 - 3-3 Quatech Inc

Warranty InformationQuatech Inc. warrants the DS-100 to be free of defects for one (5) years from the date of purchase. Quatech Inc. wi

Página 13 - 3-4 Quatech Inc

Once you have chosen the IRQ that corresponds with the setting on the Quatech DS-100 card thewindow will display “no conflicts” and the red circle wit

Página 14 - 3-5 Quatech Inc

11. Next Windows will begin the install the hardware, click “Next”.3-12 Quatech Inc.

Página 15 - 3-6 Quatech Inc

12. Next the “Completing the Add/Remove Hardware Wizard” will appear, click “Finish”.3-13 Quatech Inc.

Página 16 - 3-7 Quatech Inc

13. Next Windows will prompt you to restart the computer so the changes will take effect andshow the new ports. Select “No” to install the second port

Página 17 - “Communications Port

4. Windows 95 ConfigurationWindows 95 maintains a registry of all known hardware installed in your computer. Inside thishardware registry Windows 95

Página 18 - 3-9 Quatech Inc

6. An Install From Disk dialog box should pop up. Insert the diskette with the Quatech INFfiles on it, select the correct drive letter, and click the

Página 19 - 3-10 Quatech Inc

4.2 Viewing and Changing Resources with Device ManagerThe following instructions provide step-by-step instructions on viewing and changing resourcesof

Página 20 - 3-11 Quatech Inc

5. Click the “Resources” tab located along the top of the properties box. Confirm that theresources Windows 95 has allocated for the DS-100 match the

Página 21 - 3-12 Quatech Inc

10. Use the Logical COM Ports numbers to access the serial ports on your DS-100 throughyour software applications. Note: The Logical COM Port name i

Página 22 - 3-13 Quatech Inc

(This Page Intentionally Left Blank)3-20 Quatech Inc.

Página 23 - 3-14 Quatech Inc

© 2001, Quatech, Inc.NOTICEThe information contained in this document cannot be reproduced in any form withoutthe written consent of Quatech, Inc. Li

Página 24 - 4. Windows 95 Configuration

5. Addressing Ports5.1 Setting the addressThe base address of each port of the DS-100 is set using two DIP switch packs. When setting theaddress sele

Página 25

Switch on bit = 0Switch off bit = 1Serial 0 uses SW1 and SW2Serial 1 uses SW3 and SW4ON123456788821F48123456ON0213000000SW1SW2enable/disableON12345

Página 26

The standard addresses for serial ports COM1 and COM2 are listed in Figure 7. Recommendedaddresses for serial ports COM3 and COM4 are also listed. T

Página 27

6. Interrupt Level (IRQ)The DS-100 allows the use of any interrupt level in the range IRQ2 to IRQ7, IRQ10 to IRQ12,IRQ14, or IRQ15, selected using ju

Página 28 - 3-19 Quatech Inc

6.1 Interrupt SharingBoth ports on the DS-100 can share the same interrupt level or they can share their interrupt withanother Quatech adapter support

Página 29 - 3-20 Quatech Inc

7. External ConnectionsEIA/TIA-232-E devices are classified by their function as either Data Terminal Equipment(DTE) or Data Communication Equipment

Página 30 - 5. Addressing Ports

To simplify connections to other devices, each port on the DS-100 is equipped with a jumperblock that allows the port to be configured as either a DTE

Página 31 - Serial 1 uses SW3 and SW4

The DS-100 connects to peripheral equipment through male D-9 connectors. Adapters areavailable to convert these connectors into standard D-25 male co

Página 32 - (default)

(This Page Intentionally Left Blank)DS-100 User’s Manual 6-4

Página 33 - Serial 1

8. SpecificationsBAUD RATES:66005500430024701000115.225% TRAN20% TRAN15% TRAN10% TRAN4% TRANMAXIMUM LOAD (pF)DATA RATE(kbaud)NOTE 1: The signal trans

Página 34 - J2 --- Sharable interrupt

Declaration of ConformityManufacturer's Name: Quatech Inc.Manufacturer's Address: 5675 Hudson Industrial ParkwayHudson, Ohio 44236 (USA)App

Página 35

-12 volts 60 mA maxTEMPERATURE: Operating 0° to 70°Storage -50° to 80°HUMIDITY: 10% to 90%APPROVALS AND CERTIFICATIONS: FCC, CE, Windows 95, Windows

Página 36 - J6 -- Serial 1

9. TroubleshootingListed here are some common problems and frequent causes of those problems. Suggestions forcorrective action are given. If the in

Página 37 - (CN1 and CN2)

DS-100 User's Manual Revision 4.21March 2004P/N: 940-0048-421

Página 38 - DS-100 User’s Manual 6-4

Table of Contents8-19. Troubleshooting...6-48. Specifications...

Página 39 - 8. Specifications

1. General InformationThe Quatech, Inc. DS-100 provides two RS-232 asynchronous serial communication interfacesfor IBM-compatible personal computer s

Página 40

(This Page Intentionally Left Blank)1-2 Quatech Inc.

Página 41 - 9. Troubleshooting

2. InstallationIf the default address and interrupt settings are sufficient, the DS-100 can be quickly installed andput to use. The factory defaults

Página 42 - P/N: 940-0048-421

IRQ2IRQ3IRQ4IRQ5IRQ6IRQ7IRQ10IRQ11IRQ12IRQ14IRQ15(Diagram not to scale)SW2Serial 0SW1Serial 0SW3Serial 1SW4Serial 1J3J4Serial 0Serial 1J2J5J6Serial 0S