DSCLP/SSCLP-200/300Two and One Channel RS-422/485Low Profile Asynchronous Communications Adapterfor PCI busUser's ManualQUATECH, INC. TEL: (330)

Página 2

2.2 Signal ConnectionsThe DSCLP-200/300 provides each of two serial ports with fourdifferential signal pairs: TxD, RxD, AUXOUT, and AUXIN. TxD and R

Página 3

Jumpers J10-J23 define the options for this card:X8X4X2J3J4J5CTS0_SELAUX0_SEL0AUX0_SEL1J10J11J12RCLK0_SELTGL0_SEL0TGL0_SEL1J13J14J15RXEN0_SELCTS1_

Página 4 - Declaration of Conformity

2.3.1 CTS0_SEL, CTS1_SEL (J10, 17)With NO jumpers on J10 or J17 the mode selection is CTS=AUXIN.With Jumpers installed the mode selection is CTS=RTS.

Página 5

2.4 Clock Rate and Optional RegistersFigure 3 shows the jumper configuration as shipped from the factory, withtwo spare jumpers applied in neutral pos

Página 6 - 10 Troubleshooting

The factory default is none of these jumpers applied, which allows forsoftware control of the clock multiplier via the Options Register. The OptionsR

Página 7

3 Hardware Installation1. Turn off the power of the computer system in which the DSCLP-200/300is to be installed.2. Remove the system cover according

Página 8 - 1 General Information

4 Address Map and Special RegistersThis chapter explains how the two UARTs and special registers areaddressed, as well as the layout of those register

Página 9 - 2 Hardware Configuration

4.2 Enabling the Special RegistersThe DSCLP-200/300 contains two unique registers, an Interrupt StatusRegister and an Options Register. These registe

Página 10 - 2.2 Signal Connections

4.4 Quatech Modem Control RegisterThe Quatech Modem Control Register can be used to set up each port. Toaccess the QMCR write a 0xBF to the LCR (base

Página 11

4.5 Options RegisterThe Options Register allows software to identify the DSCLP-200/300 as aQuatech Enhanced Serial Adapter. It also allows software t

Página 12

WARRANTY INFORMATIONQuatech, Inc. warrants the DSCLP-200/300 or SSCLP-200/300 to befree of defects for five (5) years from the date of purchase.

Página 13

4.5.2 Clock Rate MultiplierA standard serial port operates at a clock speed of 1.8432 MHz. In orderto achieve higher data rates, Quatech Enhanced Ser

Página 14

5 Windows Configurations5.1 Windows Millennium 1. After inserting the DSCLP-200/300 for the first time the "Add NewHardware Wizard" wi

Página 15 - 3 Hardware Installation

5.2 Windows 20001. After inserting a DSCLP-200/300 for the first time, the "Add NewHardware Wizard will appear at start up. Click the "OK&qu

Página 16

5.3 Windows 981. After inserting a DSCLP-200/300 for the first time, the "Add NewHardware Wizard will appear at start up. Click the "Next&qu

Página 17 - 4.3 Interrupt Status Register

4. The following dialog box will display the appropriate INF file on the diskette in the drive. Click the "Next" button. 5. Window wi

Página 18

5.4 Windows 95Windows 95 maintains a registry of all known hardware installed in yourcomputer. Inside this hardware registry Windows 95 keeps track o

Página 19 - 4.5 Options Register

8. The installation utility will ask for your Windows 95 installation disks.Serial communication ports require two drivers supplied by Microsoft tofun

Página 20 - 4.5.2 Clock Rate Multiplier

5.6 Viewing Resources with Device ManagerThis discussion applies equally to Windows 95/98/ME and 2000/XP. Windows maintains a registry of all known

Página 21 - 5 Windows Configurations

3. Double click the device group "Multi-function Adapters". TheDSCLP-200/300 “parent device” belongs to this hardware class. The fulldevi

Página 22 - 5.2 Windows 2000

dialog for the specific COM port on the DSCLP-200/300. Then click theResources tab to view the Input/Output Range and Interrupt Requestresource allo

Página 23 - 5.3 Windows 98

 2006 Quatech, Inc.NOTICEThe information contained in this document cannot be reproduced in anyform without the written consent of Quatech, Inc. Lik

Página 24

5.6.1 Changing Resource Settings with Device Manager1. Start the Windows 95/98/ME Device Manager.2. Double click on the hardware class Multi-Port Seri

Página 25 - 5.4 Windows 95

The X8 clock mode locks the portshardware clock at eight times thestandard rate. The baud rate the portruns at will always be eight times therate req

Página 26 - 5.5 Windows NT

RTS routed to CTS, AUXINrouted to RCLK, and TCLKrouted to AUXOUT. Used toconnect ports transmitting atdifferent baud rates. In order tofunction, all

Página 27

Hardware automatically enablesthe transmitters whentransmitting. Transmitters willturn off three bit-times after thelast stop bit of the last charact

Página 28

full-scale for the transmit buffer and ¾-scale for the receive buffer areoptimal for most applications. Note that the FIFO option for each ofthe DSCLP

Página 29

6 Other Operating SystemsDevice drivers for Windows NT and OS/2 are also available for theDSCLP-200/300. The board can be used under DOS and other op

Página 30

6.2.1 QTPCI.EXEQuatech's "QTPCI" utility supplies the information required whenmodifying the serial port settings of the application.

Página 31

Figure 14 shows the Expert Mode display for the DSCLP-200/300 afterthe "Q" key has been pressed. The information from the Basic Mode displa

Página 32

7 External ConnectionsThe DSCLP-200/300 provides four differential communication signals perchannel. The two output signals are Transmit Data (TxD) a

Página 33

7.1 RTS/CTS HandshakeTransmission of RTS, combined with reception of CTS, allows forhardware handshaking (data flow control) between the UART and the

Página 34

Declaration of ConformityManufacturer's Name: Quatech Inc.Manufacturer's Address: 5675 Hudson Industrial ParkwayHudson, Ohio 44236 (USA)Appl

Página 35 - 6 Other Operating Systems

7.3 TCLKThis is the output clock signal used by the transmitter portion of theUART. It is generally connected to the UART's own receive clock in

Página 36 - 6.2.1 QTPCI.EXE

7.5 Half-Duplex/Full-Duplex/Auto-Toggle SelectionUsing jumper blocks J14 thru J16, the transmitters and receivers of eachchannel can be enabled and di

Página 37

Full-Duplex OperationHalf-Duplex(DTR) OperationHalf-Duplex(RTS) OperationJumpers J14-16TGL0_SEL0TGL0_SEL1J14J15RXEN0_SELJ16TGL0_SEL0TGL0_SEL1J14J15RXE

Página 38 - 7 External Connections

7.6 Termination ResistorsLine termination resistors are provided for the input signals of each of theDSCLP-200/300's RS-422/485 ports. Terminati

Página 39 - 7.2 RCLK

7.7 RS-422/485 Peripheral ConnectionThe DSCLP-200/300 connects to peripheral equipment through a 25-pinD-connector. A cable is provided to convert th

Página 40 - 7.4 AUXIN/AUXOUT Loopback

8 PCI Resource MapListed below are the PCI resources used by the DSCLP-200/300. Suchinformation may be of use to customers writing their own device d

Página 41

9 SpecificationsBus interface: PCI, 32-bit bus, Universal Voltage SignalingIBM-compatible computersDimensions: approx. 4.725" x 2.5"Serial p

Página 42 - Jumpers J14-16

10 TroubleshootingListed here are some common problems and frequent causes of thoseproblems. If the information here does not provide a solution, co

Página 43 - 7.6 Termination Resistors

DSCLP/SSCLP-200/300User's Manual Revision 1.23November 2006P/N: 940-0182-123i DSCLP/SSCLP-200/300 User's Manual

Página 44 - D-9 connector

Table of Contents356 Other Operating Systems...305.6.1 Changing Resource Settings with Device Manager.275.6 Viewing Resources wi

Página 45 - 8 PCI Resource Map

4710 Troubleshooting...469 Specifications...458 PCI Resource Map...

Página 46 - 9 Specifications

DSCLP/SSCLP-200/300 User's Manual 7